CAD Connections are the connection between CAD tools and Autodesk® CFD. During the Autodesk® CFD installation, the Connection is automatically configured for the most recent installed version of the selected CAD tools.
To add or remove a CAD launcher, run CFDConfig.exe from the Autodesk® CFD installation folder.
For more about CAD connections
These steps describe how to install the Connection for each supported CAD tool. Use these if the Connection does not appear in the CAD interface or to configure the Connection for a different installed version of the CAD tool:
Supported versions: any release
Supported versions: Inventor Professional 2022, 2023, and 2024
Supported Versions: Revit 2022, 2023 and 2024: onebox, Architectural, and MEP
The Revit launcher is installed automatically if the installer detects any of the supported versions of Revit.
To manually configure the Revit CAD Connection
The file CFDXXXX.Addin configures the addin for Revit.
To manually configure the launcher, open CFD2024.Addin in a text editor. Change the value in the
For example, if Autodesk CFD is installed in C:\Program Files\Autodesk\CFD 2024, replace the current value in the
To finish configuring the launcher, copy CFD2024.Addin to the appropriate folder, based on the installed version of Revit
Supported version: SpaceClaim 2021, 2022 and 2023
Supported versions: Creo 6.0, Creo 7.0, and Creo 8.0.
To manually configure the PTC Creo CAD Connection...
If the CFD launcher does not appear in the Creo user interface, you should add it manually:
Either append to or create a protk.dat file in the C:\Program Files\PTC\Creo X.X\Common Files\MXXX\text folder. (Note that MXXX is the date code, and you should use the appropriate folder for your system.) The file should contain the following lines, but you should modify the paths as necessary:
name CFD Desktop 2024
startup DLL
exec_file C:\Program Files\Autodesk\CFD 2024\Launchers\ProEngineer-Wildfire\Creo6\CFD_2024_Creo60.dll
text_dir C:\Program Files\Autodesk\CFD 2024\Text
revision 60
end
Supported versions: 1953, 1980, 2007, 2206, 2212
The launcher is configured by editing the custom_dirs.dat file in the UGS\NX #.#\UGII\MENUS folder. Edit this file by appending the location of your Autodesk® CFD NX launcher file. For example, if your Autodesk® CFD installation folder is C:\Program Files\Autodesk\CFD 2024, and you are using NX 1980, then add this line to the end of the file:
C:\Program Files\Autodesk\CFD 2024\Launchers\NX
Supported versions: 2021, 2022 and 2023