Use this option to define additional parameters: load type of a timber structure element and material coefficient. Access the option by clicking the More button in the Member Definition - Parameters dialog. The following dialog displays:
The lower part of the dialog defines additional conditions for round sections, i.e. unidirectional bending. If the option is selected, then during calculations of a member with round section subjected to bi-axial bending, the moments My and Mz are replaced with a resultant moment being their vector sum. The members are then subjected to unidirectional bending.
Information on recommended partial factors GammaM for material properties and resistance.
γM |
|
---|---|
Fundamental combinations: |
|
Solid timber |
1.3 |
Glued laminated timber |
1.25 |
LVL, plywood, OSB |
1.2 |
Particleboards |
1.3 |
Fiberboards, hard |
1.3 |
Fiberboards, medium |
1.3 |
Fiberboards, MDF |
1.3 |
Fiberboards, soft |
1.3 |
Connections |
1.3 |
Punched metal plates fasteners |
1.25 |
Accidental combinations: |
1.0 |
Table 2.3 Eurocode 5 (French NAD)