When you run an analysis with Helius PFA, Nastran produces the PFA Damage State variable in the output results. This variable tracks the progression of fiber and matrix constituent failure within an element. To view these results in Nastran Editor:
Since the value of PFA DAMAGE STATE is a discrete real value between 1 and 4, it is useful to change the contour plot settings so that a unique color contour is associated with each discrete integer value of PFA DAMAGE STATE. In the case of this model, where PFA DAMAGE STATE can assume values of 1.0, 2.0, or 3.0, adjust the number of contour levels so that only three colors are shown.
We see that Increment 26 represents the first matrix failure in the plate (PFA Damage State = 2).
Repeat the steps above to examine how failure propagates through the model. In Increment 59, fiber failures have stretched across the width of the plate for all of the load carrying zero degree plies. If we compare PFA DAMAGE STATE with the Maximum Single Point Constraint Force vs Load Scale Factor plot, we can identify total failure for the plate. Notice that total failure occurs well after the initial matrix failure in the model.