The diagnostics tools show more detailed information about the problems listed in the Mesh Statistics report.
The Mesh Diagnostics panel (Mesh tab > Mesh Diagnostics panel) contains the following diagnostics to check the mesh:
| Panel item | Use this diagnostic to... | Mesh type |
|---|---|---|
Aspect Ratio Diagnostic | Locate elements that have an aspect ratio above a specified limit | ![]() |
Beam L/D Ratio Diagnostic | Locate cooling channel elements that are too short or too elongated | ![]() |
Overlapping Elements Diagnostic | Locate elements that overlap or intersect, and therefore occupy the same space | ![]() |
Orientation Diagnostic | Locate elements whose top/bottom sides are defined inconsistently | ![]() |
Connectivity Diagnostic | Locate elements that are not connected to the rest of the mesh | ![]() |
Free Edges Diagnostic | Locate element edges that are not shared, which may indicate gaps or holes in the mesh | ![]() |
Collapsed Faces Diagnostic | Locate places where opposite faces of a plane share a node, and so have zero thickness | ![]() ![]() |
Dimensional Diagnostic | View model dimension values | ![]() ![]() ![]() |
Thickness Diagnostic | Check that thickness values in the mesh are set correctly | ![]() |
Occurrence Number Diagnostic | Check that occurrence numbers in the mesh are set correctly | ![]() |
Zero Area Element Diagnostic | Locate very small element | ![]() |
Dual Domain Mesh Match Diagnostic | Check that there is a good correspondence between the elements on each side of a Dual Domain mesh | ![]() ![]() |
Beam Element Count Diagnostic | Locate cooling channels meshed with insufficient elements | ![]() |
Trapped Beam Diagnostic | Locate beam elements that are too close together | ![]() |
Centroid Closeness Diagnostic | Locate triangle elements that are too close together | ![]() |
Cooling Circuit Diagnostic | Check that each cooling circuit has only one inlet and outlet | ![]() |
Bubbler/Baffle Diagnostic | Check that bubblers and baffles are modeled correctly | ![]() |