Applies to 2025.0 Update and later
Controls inter-pass dwell time to achieve a target maximum temperature
*DCTR
r1, i1, r2, r3
This card is similar to *VCTR, except it operates on different independent and dependent variables.
It is also a moving-source counterpart to *CGPT.