Use this dialog to define the lateral-buckling effective length of members.
Define your own buckling length coefficient by selecting the appropriate value for one of the available buckling modes.
![]() |
Uniformly distributed load. |
![]() |
Concentrated load at center with no intermediate lateral support. |
![]() |
x equal concentrated load at 1/x points with lateral support at 1/x points. |
![]() |
Equal end moments. |
![]() |
Other single span bending members. |
![]() |
User defined length. |
![]() |
Lateral bracings. |
![]() |
Uniformly distributed load. |
![]() |
Concentrated load at unsupported end. |
![]() |
Other cantilever bending members |
![]() |
User defined length. |
![]() |