| Attribute | Description |
|---|---|
| LoopType |
The value for this attribute is collected from the Loop Type parameter of the associative Water Loop element. |
| fluidType |
The value for this attribute is set depending on the Loop Type parameter of the associative Water Loop element. The value can be Water or Refrigerant. |
| chillerType |
The value for this attribute is collected from the Chiller Type parameter of the associative Water Loop element. |
| id |
This identification attribute is composed of the prefix "aim" (which stands for Analytical Information Model) and a sequential number. A sample value would be "aim1024". |
| Element | Description |
|---|---|
| Name |
This value is collected from the Name parameter from the associative Water Loop Revit Element. |
| CADObjectId |
This value is collected from the Element Id of the associative Water Loop Revit Element. |
| HydronicLoopId |
This specifies a unique "id" for the condenser water loop that is referenced in a VRF type Water Loop Element. |
| AnalysisParameter |
Project parameters assigned to Water Loop elements will be exported to gbXML as AnalysisParameter's. |
<HydronicLooploopType="PrimaryChilledWater"fluidType="Water"chillerType="AirCooled"id="aim23869">
<Name>CH-1</Name>
<CADObjectId>552439</CADObjectId>
</HydronicLoop>