All results fields are displayed on the results grid when opened while viewing a replay of a simulation, and on a special results page placed at the front of Property Sheets displayed while viewing a simulation replay.
Time varying results are shown with the field name in an alternate colour on the grid and property sheets. Non time varying results have the field name in the normal black type.
Database Table: __IWR_Componentset
Field Name | Help Text | Units | Database Field |
---|---|---|---|
Volume |
Total volume of water in Object Group reservoirs, calculated as the sum of Volume results of all Reservoirs included in the Object Group. Reservoir Group only. |
WN_VO |
VOLUME |
Flow |
Total flow calculated from the Flow results of all Links included in the Object Group. The flow in a link is considered to be positive if the Positive Flow box in the links grid of the Link Group Property Sheet is checked; negative if the Positive Flow box is unchecked. Link Group only. |
WN_Q |
TOTFLOW |
Electricity Tariff |
Daily rates charge specified in Electricity Tariff on Daily Rates Page and Daily Rate Usage Page. Pump Station Group only. |
WN_DRATE |
TARIFF |
Spill |
The total amount of water lost to the system due to reservoir overflow, calculated as the sum of Spill results of all Reservoirs included in the Object Group. Reservoir Group only. |
WN_VO |
SPILL |
Electric Power |
Total Electric Power used by pumps, calculated as the sum of Electric Power results of all Pump Stations included in the Object Group. Pump Station Group only. |
WN_POW |
POWER |
Outflow |
Total outflow calculated as the sum of Outflow results of all Reservoirs included in the Object Group. Reservoir Group only. |
WN_Q |
OUTFLOW |
Maximum Cost 2 |
Second monthly charge for Maximum Power used. Calculation of cost is similar to Monthly Cost of Max Power except kVA Time Interval and Max Power Demand Rate are defined in the Max Power Demand Rates 2 page of the Electricity Tariff. Pump Station Group only. |
WN_COST |
MAXCOST2 |
Maximum Cost |
Monthly charge for Maximum Power used, calculated as: PMAX / PF x Max Power Demand Rate Where: PMAX is the Maximum Averaged Electric Power (averaged over kVA Time Interval specified on the Max Power Demand Rates 1 page of the Electricity Tariff) PF is Power factor defined on the Pumping Station Parameters Page of the Pump Station Property Sheet Max Power Demand Rate is the cost defined on the Max Power Demand Rates 1 page of the Electricity Tariff Pump Station Group only. |
WN_COST |
MAXCOST |
Loss |
Total pump energy loss, calculated as the sum of Loss results of all Pump Stations included in the Object Group. Pump Station Group only. |
WN_EN |
LOSS |
Inflow |
Total inflow; calculated as the sum of Inflow results of all Reservoirs included in the Object Group. Reservoir Object Group only. |
WN_Q |
INFLOW |
Flow |
Total flow calculated as the sum of the Flow results of all Pump Stations included in the Object Group. Pump Station Group only. |
WN_Q |
FLOW |
Deficit |
Amount of water needed to maintain head at reservoir bottom level if reservoir becomes empty. Calculated as the sum of the Deficit results of all Reservoirs included in the Object Group. Reservoir Group only. |
WN_VO |
DEFICIT |
Cumulative Cost |
Total cost due to daily rates charges, from start of simulation to present timestep. If an Electricity Tariff has not been specified for the object group, the Cumulative Cost will be calculated as the sum of the Cumulative cost results of all Pump Stations included in the Object Group. Pump Station Group only. |
WN_COST |
CUMCOST |
Cost |
If an Electricity Tariff has not been specified for the Object Group, Cost will be calculated as the sum of the Cost results of all Pump Stations included in the Object Group. Pump Station Group only. |
WN_COST |
COST |
Cost of availability |
Cost of Availability specified on Application Dates Page of Electricity Tariff. Pump Station Group only. |
WN_COST |
AVCOST |
PST Energy |
Energy used at Pump Station at current timestep Pump Station Group only. |
WN_EN |
ENERGY |
PST Total Energy |
Total energy used at Pump Station during simulation. Pump Station Group only. |
WN_EN |
TENERGY |
PST Carbon Equivalent |
Applicable when carrying out Sustainability Analysis only. Energy usage expressed as a carbon dioxide equivalent. Pump Station Group only. |
WN_GHG_MASS |
CARBON |
Total PST CO2 Equivalent |
Applicable when carrying out Sustainability Analysis only. Total energy usage expressed as a carbon dioxide equivalent. Pump Station Group only. |
WN_GHG_MASS |
TCARBON |