Description: Defines a structural response used in design optimization analysis either as a constraint or an objective.
Format:
Example:
| Field | Definition | Type | Default |
|---|---|---|---|
| ID | Design response identification number. | Integer > 0 | Required |
| LABEL | User-defined label. | Character | |
| RTYPE | Response type. See table below and Remark 5. | Character | Required |
| REGION | Topology design region identification number. See Remark 2. | Integer > 0 or blank | All TOPVAR regions |
| ATTA, ATTB, ATTC | Response attributes. See table below and Remarks 4, 6, and 7. | Integer > 0 or Real or Blank |
| Response Type | Description | Response Attributes | ||
|---|---|---|---|---|
| RTYPE | ATTA (Integer > 0) | ATTB (Integer > 0) | ATTC (Integer > 0) | |
| COM | Center of mass. | Component Number (1 – 6) | Blank | Grid Identification Number |
| COMP | Compliance. | Blank | Blank | Blank |
| COMPINDX | Compliance index. | Blank | Blank | Blank |
| DISP | Displacement. | Component Number (1 - 6) | Blank | Grid Identification Number |
| EIGN | Eigenvalue. | Mode number | Blank | Blank |
| FREQ | Natural frequency. | Mode number | Blank | Blank |
| FRMASS | Mass or volume fraction. | Blank | Blank | Blank |
| GLBDISP | Global displacement. | Component Number (1-6) | Blank | Set Identification Number |
| GLBSTRS | Global stress. | Blank | Blank | Blank |
| GLBTAVE | Global average temperature. | Blank | Blank | Set Identification Number |
| GLBTEMP | Global temperature. | Blank | Blank | Set Identification Number |
| GLBTVAR | Global temperature variation. | Blank | Blank | Set Identification Number |
| HFLOW | Heat flow. | Blank | Blank | Grid Identification Number |
| LAMA | Buckling load factor. | Mode number | Blank | Blank |
| SPCF | Single point constraint force. | Component Number (1 – 6) | Blank | Grid Identification Number |
| TEMP | Temperature. | Blank | Blank | Grid Identification Number |
Remarks: