X7013 | FATAL ERROR: X7013 | The beginning history output time is larger than the ending history output time. |
Cause: | The specification of the time at which history outputs are to begin is larger than the time specified at which history outputs are to end. | |
Action: | Define an appropriate value for the beginning time that is less than the end time. | |
Remarks: | The default value for the ending restart time of zero implies that the last history time is equal to the duration. |