Add, change, or delete internal jumpers on a selected component. When wire numbers are inserted, these internal jumpers are read and wire numbers are assigned accordingly.
Find
Command entry:
AEINTERNALJUMPER
If you select to jumper two pins on a component together, an alert displays indicating that internal jumpering will cause a conflict with the existing wire number assignments. If you click Continue, an internal jumper inserts between the two pins on the component; you need to rerun the Insert Wire Numbers tool to reconcile these two different wire numbers now jumpered together. If you click Cancel, the internal jumper data is not inserted.
|
Add |
Adds an internal jumper assignment. |
|
Update |
Changes an existing jumper assignment. |
|
Delete |
Removes the selected jumper assignment from the list. |
|
Pick |
Selects the terminals to add to a jumper assignment. Try to select as close to the terminal as you can. AutoCAD Electrical toolset finds the closest connection terminal to your selected point. |
|
Show Jumpers |
Displays the current jumper assignments. AutoCAD Electrical toolset draws temporary lines between the jumpered terminals. These graphics disappear when you perform a Regen. |