Structure.BypassTarget Property

Gets or sets the bypass target structure for this inlet structure.



Namespace: Autodesk.Civil.DatabaseServices
Assembly: AeccDbMgd (in AeccDbMgd.dll) Version: 13.8.0.1516

Syntax

C#

public ObjectId BypassTarget { get; set; }

VB

Public Property BypassTarget As ObjectId
	Get
	Set

C++

public:
property ObjectId BypassTarget {
	ObjectId get ();
	void set (ObjectId value);
}

Property Value

ObjectId

Exceptions

ExceptionCondition
InvalidOperationException Thrown when this structure is not an inlet type or not located on grade.
ArgumentException Thrown when the target structure ObjectId is not a valid structure in the same network, or when attempting to set this structure as its own bypass target.

Remarks

The bypass target specifies which downstream structure should receive overflow when this inlet structure's capacity is exceeded. Only available for inlet structures (GrateInlet, CurbInlet, CombinationInlet) located on grade. Set to ObjectId.Null to indicate "Offsite" (no specific bypass target structure).