Slotted Hub Formulas for Metric Calculation

Contact pressure

Minimum hub length

Recommended values: L = (0.6 - 3) d
Force carried by one bolt

Strength check
p ≤ p A
where:
| F a | acting axial force [N] |
| T | torque [Nm] |
| d | shaft diameter [mm] |
| p | contact pressure in a joint [MPa] |
| p A | allowable pressure [MPa] |
| L | hub length [mm] |
| υ | clamping factor υ = 0.008 to 0.1 [-] |
| k s | slip safety [-] |
| F | force carried by one bolt [N]. |
| i | total number of bolts [-]. |