Slotted Hub Formulas for Metric Calculation

Contact pressure

Minimum hub length

Recommended values: L = (0.6 - 3) d
Force carried by one bolt

Strength check
p ≤ p A
where:
| | F a | acting axial force [N] |
| | T | torque [Nm] |
| | d | shaft diameter [mm] |
| | p | contact pressure in a joint [MPa] |
| | p A | allowable pressure [MPa] |
| | L | hub length [mm] |
| | υ | clamping factor υ = 0.008 to 0.1 [-] |
| | k s | slip safety [-] |
| | F | force carried by one bolt [N]. |
| | i | total number of bolts [-]. |