Maximum allowable belt working tension can be set up or it is calculated as follows
Specific belt weight is calculated as follows
T a0 , m 0 , B 0 , f max , v max are defined within belt XML data table as well as belt dimensions and available lengths and widths.
Belt power rating
P r = (k z T a - v m 2 ) v c L
Resultant service factor
Strength check fails if resultant service factor c Pr < c P .
Over-tensioning inspection
If F t max > F a or F t > F a the strength check fails as the maximum tension in belt span or static belt tension exceeded its maximum.
Recommended step if one of the criteria fails is increase belt width or driver pulley diameter. Also, the installation tension can be decreased if possible by decreasing belt tension factor k 1 . If number of teeth in mesh factor k z is less than 1.0 then consider to modify belt transmission layout.
Valid belt speed and flexing frequency inspection
If belt flex frequency f b > f max the reduced efficiency and premature belt damage might appear. The error warning is displayed.
If belt speed v > v max the error warning is displayed as the belt is not designed for such speed.
Meaning of used variables: