Data_Test - superclass: helper; super-superclass:node - 33:1 - classID: #(1935830019, 515064320) Description:
The Data_Test operator directly modifies and checks particle channel data by using sub-operators wired in a Particle Data View.
Available in 3ds Max 2014 and higher.
Constructors:
Data_Test...
DataTest...Properties:
<Data_Test>.Auto_Update     BooleanClass    default: false   --  boolean<Data_Test>.Activity_Type     Integer    default: 0   --  radiobtnIndexGet/set the state of the "Operator Activity" radio buttons.
Possible values are:
0 - Active Always (default)
1 - Active In Interval
2 - Animatable
<Data_Test>.Time_On     Integer    default: 0   --  integerGet/set the value of the "Time On" spinner available when .Activity_Type is set to 1.
<Data_Test>.Time_Off     Integer    default: 4800   --  integerGet/set the value of the "Time Off" spinner available when .Activity_Type is set to 1.
<Data_Test>.Animatable_Active     BooleanClass    default: true   --  animatable; booleanGet/set the state of the Active checkbutton available when .Activity_Type is set to 1.
<Data_Test>.Visible_Icon     BooleanClass    default: false   --  booleanGet/set the viewport icons's visibility.
This property is not exposed to the User Interface.
The Data Operator's Icon is set to False by default. Setting it to True will create a Data_Icon_Test object in the viewport, but the icon controls will not be shown in the Particle View, only in the 3ds Max Command Panel.
<Data_Test>.Icon_Type     Integer    default: 10   --  animatable; integerGet/set the icon type used when .Visible_Icon is set to True.
Possible values are:
0 - Arrow
1 - Box
2 - Circle
3 - Cone
4 - Cylinder
5 - Half Cylinder
6 - Open Cone
7 - Open Cylinder
8 - Plane
9 - Point
10 - Rectangle (default)
11 - Sphere
<Data_Test>.Icon_Parameter_1     Float    default: 10.0   --  animatable; worldUnits<Data_Test>.Icon_Parameter_2     Float    default: 10.0   --  animatable; worldUnits<Data_Test>.Icon_Parameter_3     Float    default: 20.0   --  animatable; worldUnitsGet/set the first, second and third icon parameters. Depending on the .Icon_Type value, these parameters can have different meanings.
See the table below for details:
| Icon_Type Value | Icon Type NameH | Icon_Parameter_1 | Icon_Parameter_2 | Icon_Parameter_3 | 
|---|---|---|---|---|
| 0 | Arrow | Diameter | -- | Height | 
| 1 | Box | Width | Length | Height | 
| 2 | Circle | Diameter | -- | -- | 
| 3 | Cone | Diameter | -- | Height | 
| 4 | Cylinder | Diameter | -- | Height | 
| 5 | Half Cylinder | Diameter | -- | Height | 
| 6 | Open Cone | Diameter | -- | Height | 
| 7 | Open Cylinder | Diameter | -- | Height | 
| 8 | Plane | Size | -- | -- | 
| 9 | Point | Size | -- | -- | 
| 10 | Rectangle | Width | Length | -- | 
| 11 | Sphere | Diameter | -- | -- | 
<Data_Test>.Color_Coordinated     BooleanClass    default: false   --  boolean; Auto_UpdateGet/set the state of the "Color Coordinated" checkbox.
<Data_Test>.PDView_Show_Parameters     BooleanClass    default: true   --  booleanGet/set the state of the "Parameters" option.
<Data_Test>.PDView_Show_Depot     BooleanClass    default: true   --  booleanGet/set the state of the "Depot" option.
<Data_Test>.PDView_Description_Type     Integer    default: 1   --  integerGet/set the mode of the Description panel in the Particle Data View's bottom right corner.
These modes are represented by the last 3 menu items in the Options menu, as well as the last 3 icons in the bottom right corner of the Particle Data View.
Possible values are:
1 - Description (default)
2 - Output Order
3 - Navigation
<Data_Test>.Auto_Update_On_Data_View_Close     BooleanClass    default: true   --  booleanGet/set the state of the "Auto Update On Data View Close" option.
<Data_Test>.Use_Dynamic_Names_For_New     BooleanClass    default: true   --  boolean; Use_Dynamic_Name_For_NewGet/set the state of the "Use Dynamic Names From New" option.
<Data_Test>.PDView_Divider     Integer    default: 110   --  integerGet/set the height of the horizontal divider controlling the height of the Depot and Description panels.
<Data_Test>.PDView_Width     Integer    default: 751   --  integerGet/set the Width of the Particle Data View editor window.
<Data_Test>.PDView_Height     Integer    default: 620   --  integerGet/set the Height of the Particle Data View editor window.
<Data_Test>.PDView_Origin_X     Integer    default: 0   --  integerGet/set the X coordinate of the upper left corner of the Particle Data View editor window.
<Data_Test>.PDView_Origin_Y     Integer    default: 0   --  integerGet/set the Y coordinate of the upper left corner of the Particle Data View editor window.
<Data_Test>.Default_Width     Integer    default: 50   --  integer<Data_Test>.Default_Height     Integer    default: 0   --  integer<Data_Test>.Default_Offset     Integer    default: 0   --  integer<Data_Test>.Default_Range_Max     Float    default: 100.0   --  float; Default_Range_Maximum<Data_Test>.Default_Range_Min     Float    default: 0.0   --  float; Default_Range_Minimum<Data_Test>.Default_Range_Type     Integer    default: 1   --  integer<Data_Test>.SubOperators     ArrayParameter    default: #()   --  maxObject array; SubAnimContains an array of all sub-operators in the Data_Icon Operator.
<Data_Test>.Selected_SubOperators     ArrayParameter    default: #()   --  maxObject array; SubAnimContains an array of the selected sub-operators in the Data_Icon Operator.
<Data_Test>.Groups     ArrayParameter    default: #()   --  maxObject array; SubAnimContains an array of the Group objects in the Data_Icon Operator.
<Data_Test>.Disable_By_Dependency     BooleanClass    default: false   --  boolean<Data_Test>.Repeats     Integer    default: 1   --  integer<Data_Test>.useProfileTools     BooleanClass    default: false   --  boolThis property is exposed by the Interface: profileTools.
The following common Particle Flow Interfaces are exposed by the Data_Test Class: