The Pressure, Channel (3D) result is generated from a Cool (FEM) analysis to show the distribution of pressure along a conformal cooling circuit, averaged over the cycle.
The pressure inside the conformal cooling circuits should remain evenly distributed from the inlet circuit pressure to the outlet circuit pressure. A large increase in cooling channel cross-sectional area will cause pressure drops in the cooling circuits. A thin section will also cause a pressure drop.
The information obtained from this result is also available in the analysis log.
When viewing the Pressure, Channel (3D) result, check the following: