** ERROR 304516 ** The stroke (XXX) for valve gate controller (YYY) is greater than gate channel length (ZZZ). Either the stroke specified is too large, or the valve pin is not modeled in its full open position.
This error message refers to two requirements when modeling and setting up valve gate controllers for variable speed control of the valve gate:
The valve gate must be modeled with the valve pin in the full open position, regardless of the initial state (open or closed) of the valve pin. This requirement is to avoid problems for sections where the pin comes in complete contact with the gate channel, which would result in annular beam elements with zero cross-sectional area.
The Maximum pin stroke is a required entry in the View/Edit Valve Gate Controller dialog, and refers to the distance the valve pin tip can travel, in mm, from totally open to totally closed. The valve pin tip is the section of the valve pin that comes into contact with the gate channel geometry, when fully closed.
Figure 1 Maximum pin stroke
The Maximum pin stroke cannot be greater than the gate channel length.
To access the View/Edit Valve Gate Controller dialog,