Solver message 304617

A fatal error in the model was encountered during analysis. This error occurs when an injection location is set on a tetrahedron node (number = ##) which is in the interior of the part, instead of on the surface. If no such problem is found, contact Autodesk support.

Explanation

This error occurs when an injection location is set on a tetrahedron node which is in the interior of the part, instead of on the surface.

Resolution

  1. Use the Query tool on the Mesh menu to find the node indicated in the error message.
  2. If this node is in the interior of the part and is an injection node, delete the injection boundary condition assigned to this node.
  3. Create an injection location which is on a nearby surface node.
  4. Run the analysis again.