Solver message 313390

Message text

** ERROR 313390 ** Rotational components are present in the mold model. Different rotational reference types are specified for different components. All rotational components in the model must have the same rotational type. Ensure that rotational components in the model have the same reference type.

Explanation

This error is fatal. The rotational reference point must be unique. At least two different reference points have been set for mold components in the study.

Resolution

  1. Select a first rotational component.

  2. Right-click in the Model pane and select Properties. Select Mold block (3D) and click OK.

  3. Select the Overmolding Mold Component tab.

  4. Click Set.. it and note which option is set for the Reference point (Automatic or Specify).

  5. Repeat all these steps with every rotational mold part and notice the inconsistency.

  6. Change the coordinates of the inconsistent Reference point.

  7. Click OK in the Mold block (3D) dialog.

    Note: Before clicking OK, ensure that the box Apply to all entities that share this property is deselected if both mold components have the same Mold block (3D) property.