Solver message 202196

Message text

** ERROR 202196 ** Shrinkage test adjusted mechanical properties (STAMP) is not compatible with the selected micromechanics model. Please select another 3D shrinkage model or use Rosen-Hashin CTE model.

Explanation

The STAMP shrinkage model requires you to use the default Rosen-Hashin model for calculation of the Coefficient of Thermal Expansion (CTE) of a composite polymer compound. Other CTE models are not compatible with STAMP.

Resolution