Solver message 702720
Message text
** ERROR 702720 ** The cycle time is set to Automatic in the Process Settings. For Cooling channel optimization analyses, you need to enter a specific cycle time.
Explanation
There are too many unknowns for the Cooling channel optimization analysis to calculate both the cycle time and the optimum cooling channel locations in the mold. To run a Cooling channel optimization analysis you need to specify the cycle time.
Resolution
- Run a Cool analysis on this model and select Automatic for the Injection + Packing + Cooling time in the process settings. This will calculate the optimum cycle time for this model.
- In your Cooling channel optimization analysis, select Specified for the cycle time and enter the cycle time that was calculated by the cool analysis you ran previously.
- Run a Cool analysis on the final optimized model, with an Automatic cycle time to obtain the optimum cycle time considering the new cooling channel locations.