Sets if the lap length is auto calculated or not for the specified Rebar Splice Type.
Namespace: Autodesk.Revit.DB.StructureAssembly: RevitAPI (in RevitAPI.dll) Version: 26.4.0.0 (26.4.0.0)
Syntax
C#
public void SetAutoCalculatedLapLength(
ElementId rebarSpliceTypeId,
bool autoCalculated
)
Parameters
- rebarSpliceTypeId ElementId
-
The Rebar Splice Type id.
Interactions with Rebar Splice Types can be done with the functions in RebarSpliceTypeUtils.
- autoCalculated Boolean
-
True, if the lap length is auto calculated, false otherwise.
Exceptions
| Exception | Condition |
|---|
| ArgumentException |
The rebarSpliceTypeId doesn't represent a valid Rebar Splice Type. It should be an ElementType of BuiltInCategory.OST_RebarSpliceType category.
|
| ArgumentNullException |
A non-optional argument was null
|
Remarks
If it is auto calculated, lap length value is computed based on the formula: lap length multiplier (found in splice type) * bar nominal diameter.