Create CAM files to transfer machine data to precast fabricators.
 Configuration panel
 Configuration panel  
 
		 (Configuration).
 (Configuration). 
	 | Variable | Exported File Version Availability | Syntax | |||
|---|---|---|---|---|---|
| Unitechnik 5.2 | Unitechnik 6.0 | Unitechnik 7.0 | PXML | ||
| FileName | Yes | Yes | Yes | Yes | "FileName:Length:MinLength:Padding:Alignment" Length : The maximum number of characters used from the file name. The default is 0 (unlimited). MinLength : The minimum number of characters used from the file name. The default is 0. Padding : Character used as padding between the file name other variables. The default is an underscore ( _ ). Alignment : Either l or r. The side of the text that anchors any character trimming. The default is l (left). Examples for a Revit file named 
						WallPart exported to PXML. 
					  
 | 
| Date | Yes | Yes | Yes | Yes | "Date" | 
| Time | Yes | Yes | Yes | Yes | "Time" | 
| ProdNo | Yes | Yes | Yes | Yes | "ProdNo" | 
| OrderNumber * | Yes | Yes | Yes | Yes | "OrderNumber" | 
| Component * | Yes | Yes | Yes | Yes | "Component" | 
| Storey * | Yes | Yes | Yes | Yes | "Storey" | 
| DrawingNumber * | Yes | Yes | Yes | Yes | "DrawingNumber" | 
| ProjectDescriptionLine1 - ProjectDescriptionLine4 * | Yes | Yes | Yes | No | "ProjectDescriptionLine#" # : The single digit number of the specific Product Description variable (1 - 4) | 
| BuildingSiteName * | Yes | Yes | Yes | No | "BuildingSiteName" | 
| BuildingSiteStreet * | Yes | Yes | Yes | No | "BuildingSiteStreet" | 
| BuildingSitePostCode * | Yes | Yes | Yes | No | "BuildingSitePostCode" | 
| BuildingSitePlace * | Yes | Yes | Yes | No | "BuildingSitePlace" | 
| BuildingOwnerName * | Yes | Yes | Yes | No | "BuildingOwnerName" | 
| BuildingOwnerStreet * | Yes | Yes | Yes | No | "BuildingOwnerStreet" | 
| BuildingOwnerPostCode * | Yes | Yes | Yes | No | "BuildingOwnerPostCode" | 
| BuildingOwnerPlace * | Yes | Yes | Yes | No | "BuildingOwnerPlace" | 
| DrawingDate * | Yes | Yes | Yes | Yes | "DrawingDate" | 
| DrawingRevision | No | Yes | Yes | Yes | "DrawingRevision" | 
| DrawingAuthor * | No | Yes | Yes | Yes | "DrawingAuthor" | 
| GenericOrderInfo01 - GenericOrderInfo20 * | No | No | No | Yes | "GenericOrderInfo##" ## : The two digit number of the specific Generic Order Info variable (01 - 20) | 
| AssemblyName | Yes | Yes | Yes | Yes | "AssemblyName" | 
| * This variable is defined by data in the CAM Export nodes of the Configuration dialog. | |||||
 Fabrication panel
 Fabrication panel  
 
		 (CAM Export).
 (CAM Export).