Modify floor part parameters to change the lifter settings for generating slab assemblies.
 Configuration panel
 Configuration panel  
 
   (Configuration) and navigate to:
 (Configuration) and navigate to: 
 Slab
 Slab  Solid Slab
 Solid Slab  Part
 Part 
  | Name | Description | 
|---|---|
| Lifters | |
| Type | Specifies the lifting anchor and type for the precast structural floor. | 
| Minimum Distance of Lifter to Slab Edge In Stressing Direction | Specifies the minimum distance from the lifter to any edge along the stressing direction of the slab. | 
| Minimum Distance of Lifter to Slab Edge In Shifting Direction | Specifies the minimum distance from the lifter to any edge along the shifting direction of the slab. | 
| Distances as Percentage of Slab Dimensions | Select to use a percentage of the slab dimensions instead of specific units for the in Stressing Direction and in Shifting direction parameters. | 
| Maximum Weight per Lifter | Specifies the rated tensile strength of the lifting anchor. | 
When you split a structural floor, 4 lifters are added based on this configuration. If the floor weight is higher that the capacity of the 4 lifters, a warning prompts you to change the type of lifters or to manually add additional lifters.