Here are some areas to look at when troubleshooting the Cluster Manager.
If using a version of VRED earlier than 2025.1, the Cluster Manager cannot manage renderings when using GPU Raytracing mode. Upgrading to 2025.1 will resolve this issue.
Inconsistent Frame Rate
The cluster manager updates its views periodically. During updates, there may be a drop in the frame rate. Close the cluster manager to stop updates and restore the frame rate.
Unable to Connect to a Server
bin/WIN64 folder of the VRED installation and call VREDClusterService -e -c. Check the console for error messages.Unable to Render on a Cluster Queue
Only One GPU is Used
The booking for the render queue only requests one node. However, in some cases, two may be required, one for the head node and another for the cluster node. Therefore, increase the booking to two. If there are less nodes requested than configured in the cluster config, nodes are removed from the config to match the requested number of nodes, resulting in the ONLY the head node's GPU being used, not the rendering server's GPU.