Data in the [MOUSE_PUMPS] group of the UND file is imported into the InfoWorks ICM Pump table. This topic contains details on the conversion of MOUSE pumps information to InfoWorks ICM.
|
MOUSE |
Description |
InfoWorks ICM Data Field |
||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
PUMPID |
Pump name |
Asset ID |
||||||||||||
|
LOCATION |
Node ID where pump is placed |
US Node ID |
||||||||||||
|
FLOWTO |
Node ID where flow is diverted to. If FLOWTO is not specified the pump discharges out of the system. |
DS Node ID If FLOWTO is not specified, an outfall node is created downstream of the pump, named <us node id>_out. |
||||||||||||
|
TYPENO |
Pump Type
|
Link Type
|
||||||||||||
|
DATASETID1 |
Data Set ID for Capacity Curve. Curve is defined in the TABULAR DATA section. |
A Head Discharge Table is created named using the pump primary key. Values to be imported into the head array and discharge array in the Head Discharge Table are determined from curve data in the TABULAR DATA section and OFFSETLEVEL value. See the Note on Import of MOUSE Pump Capacity Curves below. |
||||||||||||
|
OFFSETLEVEL |
Offset applied to Capacity Curve |
Used to determine values to be imported into the head array and discharge array in the Head Discharge Table associated with the pump. See the Note on Import of MOUSE Pump Capacity Curves below. |
||||||||||||
|
STARTLEVEL |
Start water level for pump |
Switch on level |
||||||||||||
|
STOPLEVEL |
Stop water level for pump |
Switch off level |
||||||||||||
|
CONTROLTYPENO |
Pump Control Type
|
Not imported as there is no equivalent in InfoWorks ICM. |
||||||||||||
|
ACCTIME |
Acceleration time for pump |
Delay |
||||||||||||
|
DECTIME |
Deceleration time for pump |
Not imported as there is no equivalent field in InfoWorks ICM. Switch-off for all InfoWorks ICM pumps is immediate. |
||||||||||||
|
MINTIMEPUMPOFF |
Minimum time the pump has to be off |
Not imported as there is no equivalent field in InfoWorks ICM. |
||||||||||||
|
MINTIMEPUMPON |
Minimum time the pump has to run |
Not imported as there is no equivalent field in InfoWorks ICM. |
||||||||||||
|
MAXSTARTLEVEL |
Maximum start water level for pump |
Not imported as there is no equivalent field in InfoWorks ICM. |
||||||||||||
|
MINSTOPLEVEL |
Minimum stop water level for pump |
Not imported as there is no equivalent field in InfoWorks ICM. |
||||||||||||
|
DATASETID2 |
Acceleration curve. Curve is defined in the TABULAR DATA section. |
Not imported as there is no equivalent field in InfoWorks ICM. |
||||||||||||
|
WETWELLSETPOINT |
Setpoint in Wet Well |
Not imported as there is no equivalent field in InfoWorks ICM. |
The Capacity Curves for MOUSE pumps are defined in the TABULAR DATA section of the UND file and are used to calculate the values to be imported into the InfoWorks ICM Head Discharge Table.
MOUSE Screw Pumps are imported to InfoWorks ICM as pumps of Link Type SCRPMP.
MOUSE Screw Pumps require a capacity curve of type QH, where H is the absolute water level in the pump's wet well. The InfoWorks ICM Head Discharge curve for a Screw Pump describes the relationship between discharge and height above the pump Base Level.
The MOUSE QH Capacity Curve and Offset Level data are used to determine the InfoWorks ICM pump Base Level value and the values to be imported into the InfoWorks ICM Head Discharge Table:
H + OFFSETLEVEL - H0
MOUSE Differential Head pumps are imported to InfoWorks ICM as pumps of Link Type ROTPMP.
The MOUSE QdH Curve and Offset Level data are used to determine the values to be imported into the InfoWorks ICM Head Discharge Table: