Change Routing Solutions

You can adjust the routing for the piping in an existing plumbing system.

  1. Select at least two pipe segments (without fittings) in the section where you want to adjust the routing or justification.
  2. Click Modify | Multi-Select tabLayout tab Routing Solutions to activate tools for adjusting the routing for the piping.

    The following routing tools are activated on the Solutions panel:

    • Solution: 1 of n

      Use the arrow buttons to cycle through the proposed solutions.

    • Fabrication Part:

      Displays Fabrication Part palette.

  3. Select a solution.
  4. Adjust the routing, adding, removing, and dragging control points as necessary.
  5. When you are satisfied with the routing, click Finish to apply the changes, or click Cancel to dismiss the routing solutions editor without applying the changes.