Default Mappings of Revit Categories to IFC Classes

The following table lists the default mapping settings of Revit categories to corresponding IFC classes. For more information about how these mappings are affected by various IFC schema versions (IFC2x3, IFC4, IFC4 CV, and IFC4.3), see notes below the table.

Revit Category IFC Class PredefinedType Exported by Default
OST_Alignments IfcBuildingElementProxy - TRUE
OST_AlignmentStationLabels IfcBuildingElementProxy - TRUE
OST_AlignmentStationLabelSets IfcBuildingElementProxy - TRUE
OST_AreaRein IfcReinforcingBar - TRUE
OST_Areas IfcSpace - TRUE
OST_Assemblies IfcElementAssembly - TRUE
OST_AudioVisualDevices IfcAudioVisualAppliance - TRUE
OST_AxisOfRotation IfcAnnotation - FALSE
OST_BridgeAbutments IfcSlab - TRUE
OST_BridgeBearings IfcBuildingElementProxy - TRUE
OST_BridgeCables IfcBuildingElementProxy - TRUE
OST_BridgeDecks IfcSlab - TRUE
OST_BridgeFraming IfcBuildingElementProxy - TRUE
OST_BridgePiers IfcColumn - TRUE
OST_BuildingPad IfcSlab - TRUE
OST_CableTray IFCCableCarrierSegment CABLETRAYSEGMENT TRUE
OST_CableTrayFitting IFCCableCarrierFittingType - TRUE
OST_Casework IfcFurniture - TRUE
OST_Ceilings IfcCovering - TRUE
OST_CenterLines IfcAnnotation - FALSE
OST_CLines IfcAnnotation - FALSE
OST_Columns IfcColumn - TRUE
OST_CommunicationDevices IfcBuildingElementProxy - TRUE
OST_Conduit IFCCableCarrierSegment CONDUITSEGMENT TRUE
OST_ConduitFitting IFCCableCarrierFitting - TRUE
OST_Cornices IfcBuildingElementProxy - TRUE
OST_Coupler IfcMechanicalFastener - TRUE
OST_Curtain_Systems IfcCurtainWall - TRUE
OST_CurtainWallMullions IfcMember MULLION TRUE
OST_CurtainWallPanels IfcPlate CURTAIN_PANEL TRUE
OST_CurtaSystem IfcCurtainWall - TRUE
OST_DataDevices IfcElectricApplianceType - TRUE
OST_DetailComponents IfcAnnotation - TRUE
OST_Doors IfcDoor - TRUE
OST_DuctAccessory IfcBuildingElementProxy - TRUE
OST_DuctCurves IfcDuctSegment - TRUE
OST_DuctFitting IfcDuctFitting - TRUE
OST_DuctInsulations IfcCovering INSULATION TRUE
OST_DuctLinings IfcCovering WRAPPING TRUE
OST_DuctTerminal IfcAirTerminal - TRUE
OST_EdgeSlab IfcBuildingElementProxy - TRUE
OST_ElectricalEquipment IfcBuildingElementProxy - TRUE
OST_ElectricalFixtures IfcBuildingElementProxy - TRUE
OST_Entourage IfcBuildingElementProxy - TRUE
OST_ExpansionJoints IfcBuildingElementProxy - TRUE
OST_FabricAreas IfcGroup - TRUE
OST_FabricationContainment IfcBuildingElementProxy - TRUE
OST_FabricationDuctwork IfcBuildingElementProxy - TRUE
OST_FabricationDuctworkInsulation IfcCovering INSULATION TRUE
OST_FabricationDuctworkLining IfcCovering WRAPPING TRUE
OST_FabricationDuctworkStiffeners IfcBuildingElementProxy - TRUE
OST_FabricationHangers IfcBuildingElementProxy - TRUE
OST_FabricationPipework IfcBuildingElementProxy - TRUE
OST_FabricationPipeworkInsulation IfcCovering INSULATION TRUE
OST_FabricReinforcement IfcReinforcementMesh - TRUE
OST_Fascia IfcCovering MOLDING TRUE
OST_FilledRegion IfcAnnotation - TRUE
OST_FireAlarmDevices IfcAlarmType - TRUE
OST_FireProtection IfcFireSuppressionTerminalType - TRUE
OST_FlexDuctCurves IfcDuctSegment FLEXIBLESEGMENT TRUE
OST_FlexPipeCurves IfcPipeSegment FLEXIBLESEGMENT TRUE
OST_Floors IfcSlab FLOOR TRUE
OST_FoodServiceEquipment IfcElectricApplianceType - TRUE
OST_Furniture IfcFurniture - TRUE
OST_FurnitureSystems IfcSystemFurnitureElement - TRUE
OST_GenericAnnotation IfcAnnotation - FALSE
OST_GenericModel IfcBuildingElementProxy - TRUE
OST_Girder IfcBeam - TRUE
OST_Grids IfcGrid - TRUE
OST_Gutter IfcPipeSegment GUTTER TRUE
OST_Hardscape IfcBuildingElementProxy - TRUE
OST_HVAC_Zones IfcZone - TRUE
OST_HorizontalBracing IfcMember BRACE TRUE
OST_ImportObjectStyles IfcBuildingElementProxy - TRUE
OST_Joist IfcBeam JOIST TRUE
OST_KickerBracing IfcMember BRACE TRUE
OST_Levels IfcBuildingStorey - TRUE
OST_LightingDevices IfcBuildingElementProxy - TRUE
OST_LightingFixtures IfcLightFixtureType - TRUE
OST_LightingFixtureSource IfcLightFixtureType - FALSE
OST_Lines IfcAnnotation - TRUE
OST_Mass IfcBuildingElementProxy - TRUE
OST_MassExteriorWall IfcWall - TRUE
OST_MassFloor IfcSlab FLOOR TRUE
OST_Massing IfcBuildingElementProxy - TRUE
OST_MassInteriorWall IfcWall - TRUE
OST_MassOpening IfcOpeningElement - TRUE
OST_MassRoof IfcRoof - TRUE
OST_MechanicalControlDevices IfcController - TRUE
OST_MechanicalEquipment IfcBuildingElementProxy - TRUE
OST_MechanicalEquipmentSetBoundaryLines IfcAnnotation - FALSE
OST_MedicalEquipment IfcMedicalDevice - TRUE
OST_MEPAncillaryFraming IfcBuildingElementPart - TRUE
OST_MEPSpaces IfcSpace - TRUE
OST_NurseCallDevices IfcSwitchingDeviceType - TRUE
OST_Parking IfcBuildingElementProxy - TRUE
OST_Parts IfcBuildingElementPart - TRUE
OST_PathRein IfcReinforcingBar - TRUE
OST_PipeAccessory IfcValveType - TRUE
OST_PipeCurves IfcPipeSegment - TRUE
OST_PipeFitting IfcPipeFitting - TRUE
OST_PipeInsulations IfcCovering INSULATION TRUE
OST_PlaceHolderDucts IfcDuctSegment - TRUE
OST_PlaceHolderPipes IfcPipeSegment - TRUE
OST_PlanRegion IfcAnnotation - FALSE
OST_Planting IfcBuildingElementProxy - TRUE
OST_PlumbingEquipment IfcBuildingElementProxy - TRUE
OST_PlumbingFixtures IfcFlowTerminal - TRUE
OST_Purlin IfcMember PURLIN TRUE
OST_Ramps IfcRamp - TRUE
OST_Rebar IfcReinforcingMesh - TRUE
OST_RebarBendingDetails IfcAnnotation - TRUE
OST_Reveals IfcOpeningElement - TRUE
OST_Roads IfcBuildingElementProxy - TRUE
OST_Roofs IfcRoof - TRUE
OST_RoofSoffit IfcCovering CLADDING TRUE
OST_Rooms IfcSpace - TRUE
OST_SecurityDevices IfcBuildingElementProxy - TRUE
OST_Signage IfcBuildingElementProxy - TRUE
OST_Site IfcSite - TRUE
OST_SiteProperty IfcBuildingElementProxy - TRUE
OST_SketchLines IfcAnnotation - FALSE
OST_SpecialityEquipment IfcBuildingElementProxy - TRUE
OST_Sprinklers IfcFireSuppressionTerminalType - TRUE
OST_Stairs IfcStair - TRUE
OST_StairsRailing IfcRailing - TRUE
OST_StairsSketchBoundaryLines IfcAnnotation - FALSE
OST_StairsSketchLandingCenterLines IfcAnnotation - FALSE
OST_StairsSketchRiserLines IfcAnnotation - FALSE
OST_StairsSketchRunLines IfcAnnotation - FALSE
OST_StructConnections IfcBuildingElementProxy - TRUE
OST_StructuralColumns IfcColumn - TRUE
OST_StructuralFoundation IfcSlab BASESLAB TRUE
OST_StructuralFraming IfcBuildingElementProxy - TRUE
OST_StructuralFramingOther IfcBuildingElementProxy - TRUE
OST_StructuralFramingSystem IfcAssembly BEAMSYSTEM TRUE
OST_StructuralStiffener IfcPlate - TRUE
OST_StructuralTendons IfcBuildingElementProxy - TRUE
OST_StructuralTruss IfcAssembly TRUSS TRUE
OST_TelephoneDevices IfcElectricApplianceType TELEPHONE TRUE
OST_TemporaryStructure IfcBuildingElementProxy - TRUE
OST_TextNotes IfcAnnotation - TRUE
OST_Topography IfcSite - TRUE
OST_Toposolid IfcGeographicElement TERRAIN TRUE
OST_Subdivision IfcGeographicElement TERRAIN TRUE
OST_Truss IfcAssembly TRUSS TRUE
OST_TrussChord IfcMember CHORD TRUE
OST_TrussWeb IfcMember - TRUE
OST_VerticalBracing IfcMember BRACE TRUE
OST_VerticalCirculation IfcTransportElement - TRUE
OST_VibrationManagement IfcBuildingElementProxy - TRUE
OST_Walls IfcWall - TRUE
OST_Windows IfcWindow - TRUE

Below are the only three mechanisms that create a schema-dependent difference, each cross-referenced against the default mapping table so only the affected categories are listed (not all 153).

Type-entity name changes (pre-IFC4 vs. IFC4 and later)

When Revit exports the "Type" object paired with an instance (e.g. a wall type, a door type), the Type entity name is not always <Instance>Type - for a few instances it depends on schema. For example, IFC2x3 doesn't have dedicated Type entities for reinforcing bars/mesh/tendons, so Revit falls back to the generic IfcReinforcingElementType . From IFC4 on, each gets its own specific Type entity.

Affected Revit Category (default mapping) Instance Class Type name in IFC2x3 Type name from IFC4 onward (IFC4 / IFC4RV / IFC4x3)
OST_Windows IfcWindow IfcWindowStyle IfcWindowType
OST_Doors IfcDoor IfcDoorStyle IfcDoorType
OST_AreaRein , OST_PathRein IfcReinforcingBar IfcReinforcingElementType IfcReinforcingBarType
OST_Rebar IfcReinforcingMesh IfcReinforcingElementType IfcReinforcingMeshType
(not in default table - IfcTendon / IfcTendonAnchor map to IfcBuildingElementProxy by default) IfcTendon / IfcTendonAnchor IfcReinforcingElementType IfcTendonType / IfcTendonAnchorType

PredefinedType values deprecated in IFC4x3

Only IFC4x3 has deprecated PredefinedType values - IFC2x3/IFC4/IFC4RV have none registered. None of the default-mapped rows below actually set one of these deprecated values by default (the default table leaves PredefinedType blank for all of them) - this only becomes relevant if a user manually assigns one of the listed values in the category-mapping UI.

Affected Revit Category (default mapping) Default IFC Class PredefinedType values deprecated in IFC4x3 only
All 39 categories default-mapped to IfcBuildingElementProxy : OST_Alignments , OST_AlignmentStationLabels , OST_AlignmentStationLabelSets , OST_BridgeBearings , OST_BridgeCables , OST_BridgeFraming , OST_CommunicationDevices , OST_Cornices , OST_DuctAccessory , OST_EdgeSlab , OST_ElectricalEquipment , OST_ElectricalFixtures , OST_Entourage , OST_ExpansionJoints , OST_FabricationContainment , OST_FabricationDuctwork , OST_FabricationDuctworkStiffeners , OST_FabricationHangers , OST_FabricationPipework , OST_GenericModel , OST_Hardscape , OST_ImportObjectStyles , OST_LightingDevices , OST_Mass , OST_Massing , OST_MechanicalEquipment , OST_Parking , OST_Planting , OST_PlumbingEquipment , OST_Roads , OST_SecurityDevices , OST_Signage , OST_SiteProperty , OST_SpecialityEquipment , OST_StructConnections , OST_StructuralFraming , OST_StructuralFramingOther , OST_StructuralTendons , OST_TemporaryStructure , OST_VibrationManagement IfcBuildingElementProxy COMPLEX , ELEMENT , PARTIAL
OST_Walls , OST_MassExteriorWall , OST_MassInteriorWall IfcWall POLYGONAL , STANDARD
OST_CableTrayFitting IFCCableCarrierFittingType CROSS , REDUCER , TEE
OST_ConduitFitting IFCCableCarrierFitting CROSS , REDUCER , TEE
OST_FireProtection , OST_Sprinklers IfcFireSuppressionTerminalType SPRINKLERDEFLECTOR
(none in default table map to IfcFooting ) IfcFootingType CAISSON_FOUNDATION
(none in default table map to IfcGeographicElement with this PredefinedType - OST_Toposolid / OST_Subdivision use TERRAIN , which is unaffected) IfcGeographicElementType SOIL_BORING_POINT

Entities marked deprecated/unsupported - not used as defaults, but relevant caveats

None of these entities are used as a default mapping target in the category table (the table maps to the base class, e.g., IfcWall, never the *StandardCase variant.

Entity Deprecated in Notes
IfcProxy , IfcDoorStyle , IfcWindowStyle , Ifc*StandardCase , Ifc*ElementedCase IFC4 and IFC4x3 Superseded by the newer Type-entity pattern (see section 1)
IfcElectricalElement , IfcEquipmentElement IFC2x3 only Not deprecated in any other schema
IfcBuilding , IfcBuildingStorey All schemas (IFC2x3 through IFC4x3) Not a schema difference - flagged unsupported for "Export As" universally. Explains why OST_Levels (default-mapped to IfcBuildingStorey ) is always greyed out in the category-mapping UI regardless of the selected schema.