The geometry requirements (parameters) for a flanged connector are listed below. The specification used in this example is “ASME B16.5”.
Parameter (Dimension) | Value |
Diameter | Should be set according to the catalog |
Extension | = 0 |
Snap Offset | = 2*0.025 (There is 0.05 inch distance between two pieces of Flange.) |
Body Thickness | = Width of Flange (tf +raise face) |
Body Length | = Thickness of Flange (O) |
Body Set Back | = 0 |
Swage Set Back | = 0 |