Connectors with Swage Geometry

Some items include a connector with a swage. For these types of connectors, set the Swage Set Back and Swage Length parameters.

The geometry requirements (parameters) for a female connector with swage geometry are listed below. The specification used in this example is “ASME B1.20.1”.

Parameter (Dimension) Value
Diameter

Should be set according to catalog.

Extension

= Body length

Snap Offset

=-2*Extension

Body Thickness = Width of band (c)
Body Length = Body length (a-Za)
Body Set Back = 0
Swage Set Back = - Body length
Swage Length = Swage Length (b)