Some items include a connector with a swage. For these types of connectors, set the Swage Set Back and Swage Length parameters.
The geometry requirements (parameters) for a female connector with swage geometry are listed below. The specification used in this example is “ASME B1.20.1”.
Parameter (Dimension) | Value |
Diameter |
Should be set according to catalog. |
Extension |
= Body length |
Snap Offset |
=-2*Extension |
Body Thickness | = Width of band (c) |
Body Length | = Body length (a-Za) |
Body Set Back | = 0 |
Swage Set Back | = - Body length |
Swage Length | = Swage Length (b) |