Filtration

Filtration Control represents a flow through a filter bed.

The following equation is used:

where

Q = Discharge

A = Area

K = Permeability Coefficient / Safety Factor

d = Filter depth

h = Water depth

Note: The analysis will considers the head based on downstream conditions.

Specification

Permeability Coefficient - The rate at which water stored in the stormwater control percolates into the filter medium within the structure.  

Safety Factor - The required safety factor.

Bed Depth - The depth of the planting soil bed.

Area - The surface area of the filter bed.

Invert Elevation - The invert elevation of the outlet.