Pump Outlets allow a depth flow relationship to be entered in order to represent the performance curve of a pump.
Invert Elevation - The invert elevation of the control.
Spreadsheet - Enter the required flow rate for each depth of water.
Depth Increments - The depth increment can be set by entering the required increment into the Depth Incr. field and clicking the Apply button (arrow head).
Alternatively the depths and outflow rates can be entered freehand into the table.
Import - Data can be loaded from .TXT, .CSV or Excel file using the Import option which utilizes the Universal Importer.