The Rainwater Tank is considered as two distinct volumes. The Retention volume provides a Harvest Flow which is a constant outflow which is lost from analysis. The Detention volume provides storm water attenuation and an outflow which, in analysis, continues to the next node. Any overflow also passes to the next node.
Physically the Tank may be one tank or two joined by a pipe. In InfoDrainage the two volumes can be described and controlled separately but there is no attenuation allowed between the two volumes.
If the Retention volume is disabled then there is no retention storage or Harvest Flow. If the Retention volume is disabled the Inflow passes directly into the Detention volume which can overflow to the next node. If both volumes are disabled then Inflow passes straight to the Overflow. The diagram below shows how the movement of flow (and pollution load) are analyzed
If the Retention Volume is enabled:
If the Detention Volume is enabled:
Otherwise (Detention volume is disabled), if the Retention Volume is enabled: