The Batch Simulation Manager is used to run models for numerous user-selected scenarios in a single operation. This command is especially useful when several simulations are simultaneously required for a large model. With the Batch Simulation Manager, you can select the desired scenarios and run each model in a batch process. The Batch Simulation Manager is only available for standard simulations and not available for Fireflow, SCADA, (etc., model runs).
To activate the Batch Simulation Manager, from the InfoWater Model Explorer > Tools >Batch Simulation.
Active Scenario - Lists the active (currently loaded scenario) before starting the batch run process and the scenario currently being processed while the batch run is in progress.
Simulation Type - Indicates the type of simulation the Batch Run Manager will execute. Select from a standard hydraulic/water quality simulation, a multi-fireflow simulation or a SCADA simulation.
Error Handling Option - Indicates how the simulation will proceed should an error occur during simulation of one of the scenarios during a batch (multi-scenario) simulation run.
Update Output Relate - If selected, any active output relates will be updated.
Scenario Selection - Lists all of the scenarios currently available in the open project including the default scenario BASE and all custom scenarios defined by the user. Only selected (highlighted) scenarios will be included in the batch run. To include scenarios in the batch run, click once on the scenario name with the mouse. That scenario becomes highlighted. To choose additional scenarios to add to the list, hold the shift key down while selecting the additional scenarios.
Run Mode - Used to control how the run is managed. Select from the following options from the drop-down menu:
Select All - Will select all scenarios in the list.
Clear All - Will clear all selected scenarios.
Move Up - Will change the execution order by moving the selected scenario up the list.
Move Down - Will change the execution order by moving the selected scenario down the list.
Run - Runs the Batch Simulation. The Run button is disabled until you choose at least two scenarios for inclusion in the batch run.
Close - Closes the Batch Simulation Manager.
After a batch simulation is run, the last scenario simulated will be available as the *active* Standard output source. Other scenarios simulated will be available and loaded as user-defined output sources identified by the scenario names, for example Future1.Standard and Future2.Standard. To review results associated with those scenarios, from the Output Report Manager, choose the desired output source from the All Output Sources box and select either graph or report.