Data Tables - Pump Energy Data

All the pump energy data is contained in this table. Refer to the section on Energy management for more information.

ID - The Pump ID.

ENG_PATN - Enter the Energy Charge Pattern here. The pattern needs to be prior created. Refer to the section on Patterns for details.

DMD_PATN - Refers to the Demand Charge Pattern. The pattern needs to be prior created.

ENG_RATE - Enter the Energy Rate here.

Note: You may add rows to this table using the Insert  or the Append  icon. You may also delete rows from this table by using the Delete  icon. This may provide a quick method to assign Energy data to a number of pumps. Also it provides a means to edit Energy data on a global level on the fly.