The Pump hydraulic tables contain all the modeling information for pumps as shown below:
ID - The Pump ID. This field cannot be deleted, modified or altered.
TYPE - Refers to the pump type. InfoWater allows for 4 different pump types. Refer to the section on Pumps for more information.
ELEVATION - Refers to the elevation of the pump. This is a required field.
DIAMETER - Diameter of the pump. This is an optional field and is required only while calculating the NPSH for pumps.
HP - If the pump type chosen is a Constant Power Input pump, then enter the pump Horsepower.
SHUT_HEAD - Enter the shut-off head for 2: Exponential 3-Point Curve type pumps.
DSGN_HEAD - Enter the Design head for 2: Exponential 3-Point Curve pumps and 1: Design Point Curve type pumps.
DSGN_FLOW - Enter the Design flow for 2: Exponential 3-Point Curve pumps and 1: Design Point Curve type pumps.
HIGH_HEAD - Enter the High head for 2: Exponential 3-Point Curve type pumps
HIGH_FLOW - Enter the High flow for 2: Exponential 3-Point Curve type pumps
CURVE - For 3: Multiple Point curve type pump enter the cure ID. For 3: Multiple Point curve pumps, the only required field is Elevation.
NPSH_CURVE - Enter the NPSH curve ID if you wish to conduct a Net Positive suction head analysis for pumps.