Data Tables - Tank Mixing Data

This table contains the Tank Mixing data such as 0: Complete Mixing, 1:Two-Compartment etc. Refer to the section on Water Quality for more information.

ID - The tank ID.

MODEL - The quality source type.

VOLUME - Enter the decimal volume that represents the fraction of the total tank volume devoted to the inlet/outlet compartment in the case of a 1: Two-Compartment type tank.

Important: InfoWater Pro reports tank or reservoir water quality at the inlet / outlet of these nodes. Separate analyses, such as computational fluid dynamics modeling, may be warranted to evaluate actual mixing conditions or constituent growth and decay reactions within tanks or reservoirs.
Note: You may add rows to this table using the Insert  or the Append  icon. You may also delete rows from this table by using the Delete  icon.