The SCADA tab provides the ability to run simulations that take into account the conditions measured within the distribution network via the Supervisory Control and Data Acquisition (SCADA) system.
A SCADA system stores information useful for network many modeling applications. This system compiles both real-time and historical operational data for local and remote facility sites. Such information is useful to define input data conditions for InfoWater Pro including loading conditions in temporal format for pressure zone and system demands, boundary conditions for reservoir and tank water levels, as well as pipe status and pump and control valve settings. The SCADA output for pressure and flow measurements can also be used in model calibration to verify the reliability of the model results. The ability to interface with SCADA systems can offer a number of benefits including at a minimum:
These benefits can only be realized if both systems communicate properly with one another, so that information gathered by the SCADA system can be shared with InfoWater Pro and could be used in simulation runs. The intent is to update InfoWater Pro with the most recent SCADA data.
The best way to integrate InfoWater Pro securely with SCADA data is through Info360. This approach involves pushing encrypted data to the Info360 cloud for data cleanup, processing, and visualization. InfoWater Pro can use this data on-demand for simulations and publish results back to Info360 dashboards for comparison and review.
The alternative is to manually create SDA files which are used in the engine to enforce boundary conditions on the model based on sensor data.
SCADA tab is available in the Run manager window, which allows you to create a simulation based on SCADA data.
Fields | Descriptions | ||||||
Demand Adjustment Method |
Select the appropriate option here and then enter the value in Demand Adjustment Factor field. Show More
|
||||||
Demand Adjustment Factor |
Specify the demand Adjustment factor. The factor will be dependent on the Demand Adjustment method and is a means to normalize the demands to reflect your true SCADA demands. |
||||||
Info360 |
When Info360 is selected in the SCADA Input Data File section, the SCADA Event Manager is used to control which timeseries event data from Info360 will be used in the simulation.
|
||||||
Browse SDA File |
When this option is selected in the SCADA Input Data File section, an SDA text file can be mapped directly to be used in the simulation. Note that any objects being controlled by the SDA File will need to have a SCADA Control setup ahead of time. |
||||||
Start Reporting fromSCADA Data Instant |
When turned on, this option will delay all output reporting until the first timestep found in the SCADA file provided to the engine. In addition, the simulation will be extended to the final timestep reported in the SCADA file if necessary to span all measured data. |
When you select the Browse SDA File checkbox in the Run Manager dialog box, you can manually configure and map a SDA file to the simulation.
The following is an example of an SDA text file configured to update the initial conditions of several objects and modify the status of two pumps at hour 4.
After stating the time and day in your SDA file, controls are listed by stating the Keyword, Sensor ID, and Value.
Sensor ID’s must be defined for each model object using the SCADA Control definition, as shown below.
The following Keywords can be used in the SDA file:
Keyword |
Control Action |
Reservoir_Control |
Update reservoir level |
Tank_Control |
Update tank level |
Pump_Control_Status |
Update the status of the pump |
Pump_Control_Speed |
Update the speed setting on the pump |
Valve_Control |
Update the setting of the valve |