Specifies which fields to include in the report, the field order, and the field labels.
FindCommand entry: AESCHEMATICREPORT
Select Connector Details from the report list. Run the report and click Change Report Format on the Report Generator dialog box.
List of Options
The following options are displayed.
- Available Fields
- Lists the available fields for the report, including fields added with the User Attributes command. Select a field from the list to add it to the report.
- Fields to Report
- Specifies the fields to display in the report, and the field order.
- Remove
- Removes the selected field from the Fields to Report list.
- Remove All
- Removes all the fields from the Fields to Report list.
- Move Up
- Moves the selected field up one spot in the Fields to Report list.
- Move Down
- Moves the selected field down one spot in the Fields to Report list.
- Change Field Name/Justification
- Specifies the field label and justification for the selected field. Note: The vertical justification is used only when the report is inserted as a table.
Available Fields
- CONNECTOR
- Connector tag value
- PIN
- Wire connection terminal pin number
- TYPE
- P = Plug and J = Jack
- WIRENO
- Wire number
- DESC1-3
- Description 1-3 values
- MFG
- Manufacturer or vendor name
- CATALOG
- Catalog part number assignment
- ASSYCODE
- Assembly code value linking the catalog value to subassembly items
- REF
- Line reference, X-Y grid reference, or X Zone reference of the connector
- INST
- Installation value
- LOC
- Location value
- SH
- Sheet value (%S) for the drawing where the connector is located
- SHDWGNAM
- Drawing value (%D) for the drawing where the connector is located
- HDL
- Handle number of the connector block
- RATING1-12
- Rating 1 - 12 values
- DWGIX
- DWGIX value, as listed in FILETIME table of project database, for the drawing where the connector is located