Specifies which fields to include in the report, the field order, and the field labels.
FindCommand entry: AESCHEMATICREPORT
Select Terminal Plan from the report list. Run the report and click Change Report Format on the Report Generator dialog box.
List of Options
The following options are displayed.
- Available Fields
- Lists the available fields for the report, including fields added with the User Attributes command. Select a field from the list to add it to the report.
- Fields to Report
- Specifies the fields to display in the report, and the field order.
- Remove
- Removes the selected field from the Fields to Report list.
- Remove All
- Removes all the fields from the Fields to Report list.
- Move Up
- Moves the selected field up one spot in the Fields to Report list.
- Move Down
- Moves the selected field down one spot in the Fields to Report list.
- Change Field Name/Justification
- Specifies the field label and justification for the selected field. Note: The vertical justification is used only when the report is inserted as a table.
Available Fields
Each line item in the report can include two connected components, referred to as the From and To components. Whether a component is considered the From or the To component is based on the wire sequence for the wire network. The wire sequence can be defined specifically or can default to the Tag/Wire Number/Wire Sequence Order defined on the Drawing Format tab of the Drawing Properties dialog box. The From field labels end in a "1" and the To field labels end in a "2".
- INST1
- Installation value on the From component
- LOC1
- Location value on the From component
- CMP1
- Tag value on the From component
- PIN1
- Terminal number on the wire connection attribute of the From component
- PD1
- TERMDESC value on the wire connection of the From component
- LAYCMP1
- Layer of the wire connected to the From component
- CBL1
- Cable tag on the wire connected to the From component
- CBLWC1
- Cable wire or cable core color connected to the From component
- WNUM1
- Wire number on the wire connected to the From component
- LAYTRM1
- Layer of wire connecting the From component to the terminal
- STRIP-ID
- Tagstrip value for the terminal
- TD1
- TERMDESC value on the wire connection of the terminal connecting to the From component
- TERM
- Terminal number
- TD2
- TERMDESC value on the wire connection of the terminal connecting to the To component
- TINST
- Installation value on the terminal
- TLOC
- Location value on the terminal
- LAYTRM2
- Layer of wire connecting the To component to the terminal
- WNUM2
- Wire number on the wire connected to the To component
- CBL2
- Cable tag on the wire connected to the To component
- CBLWC2
- Cable wire or cable core color connected to the To component
- LAYCMP2
- Layer of the wire connected to the To component
- PD2
- TERMDESC value on the wire connection of the To component
- PIN2
- Terminal number on the wire connection attribute of the To component
- CMP2
- Tag value on the To component
- INST2
- Installation value on the To component
- LOC2
- Location value on the To component
- SH
- Sheet value (%S) for the drawing where the terminal is located
- REF
- Line reference, X-Y Grid, or X Zone location of the terminal
- HDL
- Entity handle value of the terminal block
- XDIR1
- Wire connection direction code and suffix for the From component
- XDIR2
- Wire connection direction code and suffix for the To component
- DWGIX
- DWGIX value, as listed in FILETIME table of project database, for the drawing where the terminal is located
- W01USER1-W10USER1
- Attribute values from the wire number block on the wire connecting the From component
- W01USER2-W10USER2
- Attribute values from the wire number block on the wire connecting the To component