Specifies which fields to include in the report, the field order, and the field labels.
FindCommand entry: AESCHEMATICREPORT
Select PLC I/O Address and Descriptions from the report list. Run the report and click Change Report Format on the Report Generator dialog box.
List of Options
The following options are displayed.
- Available Fields
- Lists the available fields for the report, including fields added with the User Attributes command. Select a field from the list to add it to the report.
- Fields to Report
- Specifies the fields to display in the report, and the field order.
- Remove
- Removes the selected field from the Fields to Report list.
- Remove All
- Removes all the fields from the Fields to Report list.
- Move Up
- Moves the selected field up one spot in the Fields to Report list.
- Move Down
- Moves the selected field down one spot in the Fields to Report list.
- Change Field Name/Justification
- Specifies the field label and justification for the selected field. Note: The vertical justification is used only when the report is inserted as a table.
Available Fields
- TAGNAME
- PLC symbol or module's tag value
- ADDR
- PLC I/O point's address
- TERM
- PLC I/O point's terminal number
- PD1
- PLC I/O point's terminal TERMDESC value
- DESCA-DESCE
- PLC I/O point's five description values
- LREF
- Line reference, X-Y grid reference, or X Zone reference of the PLC symbol or module
- WIRENO
- Wire number
- INST
- Installation value
- LOC
- Location value
- MFG
- Manufacturer or vendor name
- CAT
- Catalog part number assignment
- ASSYCODE
- Assembly code value linking the catalog value to subassembly items
- LINE1
- PLC module's LINE1 attribute description text
- LINE2
- PLC module's LINE2 attribute description text
- HDL
- Handle number of the PLC symbol or module block
- XTERMHDL
- Entity handle number for the X?TERMxx wire connection attribute
- TERMCODE
- Wire connection X?TERMxx attribute suffix (the "xx")
- SH
- Sheet value (%S) for the drawing where the PLC symbol or module is located
- SHDWGNAM
- Drawing value (%D) for the drawing where the PLC symbol or module is located
- IEC_P
- Project value (%P) value for the drawing where the PLC symbol or module is located
- IEC_I
- Installation value (%I) value for the drawing where the PLC symbol or module is located
- IEC_L
- Location value (%L) value for the drawing where the PLC symbol or module is located
- SEC
- Section value for the drawing where the PLC symbol or module is located
- SUBSEC
- Sub-section value for the drawing where the PLC symbol or module is located
- DWGIX
- DWGIX value, as listed in FILETIME table of project database, for the drawing where the PLC symbol or module is located