Specifies which fields to include in the report, the field order, and the field labels.
FindCommand entry: AESCHEMATICREPORT
Select PLC I/O Component Connection from the report list. Run the report and click Change Report Format on the Report Generator dialog box.
List of Options
The following options are displayed.
- Available Fields
- Lists the available fields for the report, including fields added with the User Attributes command. Select a field from the list to add it to the report.
- Fields to Report
- Specifies the fields to display in the report, and the field order.
- Remove
- Removes the selected field from the Fields to Report list.
- Remove All
- Removes all the fields from the Fields to Report list.
- Move Up
- Moves the selected field up one spot in the Fields to Report list.
- Move Down
- Moves the selected field down one spot in the Fields to Report list.
- Change Field Name/Justification
- Specifies the field label and justification for the selected field. Note: The vertical justification is used only when the report is inserted as a table.
Available Fields
- PLCWNUM
- Wire number associated with PLC I/O point
- PLCTAG
- PLC symbol or module's tag value
- PLCADDR
- PLC I/O point's address
- PLCDESCA-PLCDESCE
- PLC I/O point's five description values
- PLCTERM
- PLC I/O point's terminal number
- PLCTERMDESC
- PLC I/O point's terminal TERMDESC value
- PLCINST
- PLC I/O module's installation value
- PLCLOC
- PLC I/O module's location value
- WLAY
- Layer of the wire connected to the PLC I/O point
- PLCMFG
- PLC I/O module's manufacturer or vendor name
- PLCCAT
- PLC I/O module's catalog part number assignment
- PLCASSYCODE
- PLC I/O module's assembly code value linking the catalog value to subassembly items
- PLCTERMCODE
- PLC I/O wire connection X?TERMxx attribute suffix (the "xx")
- PLCDWGIX
- DWGIX value, as listed in FILETIME table of project database, for the drawing where the PLC symbol or module is located
- PLCHDL
- Handle number of the PLC symbol or module block
- PLCLINE1
- PLC module's LINE1 attribute description text
- PLCLINE2
- PLC module's LINE2 attribute description text
- CMPTAG
- Tag value on the connected component
- CMPDESC1-3
- Description attribute values 1 - 3 on the connected component
- CMPINST
- Installation value on the connected component
- CMPLOC
- Location value on the connected component
- CMPTERM
- Terminal (TERMxx attribute) value on the connected component
- CMPTERMDESC
- Terminal description (TERMDESCxx attribute) value on the connected component
- CMPMFG
- Manufacturer value on the connected component
- CMPCAT
- Catalog part number value on the connected component
- CMPASSYCODE
- Assembly code value on the connected component
- CMPDWGIX
- DWGIX value, as listed in FILETIME table of project database, for the drawing where the connected component is located
- CMPHDL
- Handle number of the connected component
- CMPBLKNAM
- Block name of the connected component
- TERMTAG
- Tagstrip value on the connected terminal
- TERMINST
- Installation value on the connected terminal
- TERMLOC
- Location value on the connected terminal
- TERMTERM
- Terminal (TERMxx attribute) value on the connected terminal
- TERMTERMDESC
- Terminal description (TERMDESCxx attribute) value on the connected terminal
- TERMMFG
- Manufacturer value on the connected terminal
- TERMCAT
- Catalog part number value on the connected terminal
- TERMASSYCODE
- Assembly code value on the connected terminal
- TERMDWGIX
- DWGIX value, as listed in FILETIME table of project database, for the drawing where the connected terminal is located
- TERMHDL
- Handle number of the connected terminal
- TERMBLKNAM
- Block name of the connected terminal
- CBL
- Cable tag
- CBLWC
- Cable wire or cable core color
- CBLHDL
- Handle value for the cable marker block