Specifies which fields to include in the report, the field order, and the field labels.
FindCommand entry: AEPANELREPORT
Select Wire Connection from the report list. Run the report and click Change Report Format on the Report Generator dialog box.
List of Options
The following options are displayed.
- Available Fields
- Lists the available fields for the report, including fields added with the User Attributes command. Select a field from the list to add it to the report.
- Fields to Report
- Specifies the fields to display in the report, and the field order.
- Remove
- Removes the selected field from the Fields to Report list.
- Remove All
- Removes all the fields from the Fields to Report list.
- Move Up
- Moves the selected field up one spot in the Fields to Report list.
- Move Down
- Moves the selected field down one spot in the Fields to Report list.
- Change Field Name/Justification
- Specifies the field label and justification for the selected field. Note: The vertical justification is used only when the report is inserted as a table.
Available Fields
- TAGNAME
- Component tag value
- PIN
- Terminal number on the wire connection attribute
- WIRENO
- Wire number
- WTYPE
- Wire layer
- INST
- Installation value
- LOC
- Location value
- MOUNT
- Mount value
- GROUP
- Group value
- END1
- Component tag and pin value on the From component based on the schematic wire network
- END2
- Component tag and pin value on the To component based on the schematic wire network
- MFG
- Manufacturer or vendor name
- CAT
- Catalog part number assignment
- ASSYCODE
- Assembly code value linking the catalog value to subassembly items
- BLKNAME
- Block name
- ITEM
- Item number
- DWGIX
- DWGIX value, as listed in the FILETIME table of the project database, for the drawing where the component is located
- HDL
- Handle number of the component block
- CATEGORY
- Type of component (J = plug-jack connector, P = PLC I/O, C = cable marker, FP = Panel Footprint, FPT = terminal footprint)
- PDESC
- Wire connection description attribute value
- SFX
- Values of R or L; used for terminal block symbols where we identify the wire annotation attributes with an R or L for Right or Left of the symbol
- SH
- Sheet value (%S) for the drawing where the component is located
- SHDWGNAM
- Drawing value (%D) for the drawing where the component is located
- X
- Wire connection's physical X-coordinate value
- Y
- Wire connection's physical Y-coordinate value
- Z
- Wire connection's physical Z-coordinate value
- CBL
- Cable tag
- TEXT
- Wire annotation text