Specifies which fields to include in the report, the field order, and the field labels.
FindCommand entry: AEPANELREPORT
Select Terminal Exception from the report list. Run the report and click Change Report Format on the Report Generator dialog box.
List of Options
The following options are displayed.
- Available Fields
- Lists the available fields for the report, including fields added with the User Attributes command. Select a field from the list to add it to the report.
- Fields to Report
- Specifies the fields to display in the report, and the field order.
- Remove
- Removes the selected field from the Fields to Report list.
- Remove All
- Removes all the fields from the Fields to Report list.
- Move Up
- Moves the selected field up one spot in the Fields to Report list.
- Move Down
- Moves the selected field down one spot in the Fields to Report list.
- Change Field Name/Justification
- Specifies the field label and justification for the selected field. Note: The vertical justification is used only when the report is inserted as a table.
Available Fields
- TAGNAME
- Terminal strip value, terminal number, and the wire number value on the terminal
- INST
- Installation value
- LOC
- Location value
- COMMENT
- Explanation of the exception issue
- PNL
- Value of the mismatched property on the panel footprint
- SCHEM
- Value of the mismatched property on the schematic component
- HDL
- Handle number of the block
- SH
- Sheet value (%S) for the drawing
- SHDWGNAM
- Drawing value (%D) for the drawing
- FULLFILENAME
- Drawing .dwg file name, with full path
- FILENAME
- Drawing .dwg file name