Specifies which fields to include in the report, the field order, and the field labels.
FindCommand entry: AESCHEMATICREPORT
Select Cable From/To from the report list. Run the report and click Change Report Format on the Report Generator dialog box.
List of Options
The following options are displayed.
- Available Fields
- Lists the available fields for the report, including fields added with the User Attributes command. Select a field from the list to add it to the report.
- Fields to Report
- Specifies the fields to display in the report, and the field order.
- Remove
- Removes the selected field from the Fields to Report list.
- Remove All
- Removes all the fields from the Fields to Report list.
- Move Up
- Moves the selected field up one spot in the Fields to Report list.
- Move Down
- Moves the selected field down one spot in the Fields to Report list.
- Change Field Name/Justification
- Specifies the field label and justification for the selected field.
Note: The vertical justification is used only when the report is inserted as a table.
Available Fields
Each line item in the report can include two connected components, referred to as the From and To components. Whether a component is considered the From or the To component is based on the wire sequence for the wire network. The wire sequence can be defined specifically or can default to the Tag/Wire Number/Wire Sequence Order defined on the Drawing Format tab of the Drawing Properties dialog box. The From field labels end in a "1" and the To field labels end in a "2".
- WIRENO
- Wire number
- LOC1
- Location value on the From component
- CMP1
- Tag value on the From component
- PIN1
- Terminal number on the wire connection attribute of the From component
- LOC2
- Location value on the To component
- CMP2
- Tag value on the To component
- PIN2
- Terminal number on the wire connection attribute of the To component
- WLAY1
- Layer of the wire connected to the From component
- WLAY2
- Layer of the wire connected to the To component
- REF1
- Line reference, X-Y Grid, or X Zone location of the From component
- REF2
- Line reference, X-Y Grid, or X Zone location of the To component
- SH1
- Sheet value (%S) for the drawing where the From component is located
- SH2
- Sheet value (%S) for the drawing where the To component is located
- CBL
- Cable tag
- CBLWC
- Cable wire or cable core color
- CBLLOC
- Cable location value
- CBLMFG
- Cable manufacturer value
- CBLCAT
- Cable catalog part number
- CBLASMB
- Cable ASSYCODE assignment
- CBLDESCCAT
- 3rd field in the catalog database table for the catalog value on the cable
- CBLQ1CAT
- 4th field in the catalog database table for the catalog value on the cable
- CBLQ2CAT
- 5th field in the catalog database table for the catalog value on the cable
- CBLMISC1CAT - CBLMISC2CAT
- Miscellaneous fields in the catalog database table for the catalog value on the cable, fields 6-7
- CBLUSER1CAT - CBLUSER3CAT
- User fields in the catalog database table for the catalog value on the cable, fields 11-13
- DESC1CBL-DESC3CBL
- Cable description values 1 - 3
- CBLP1C2
- Cable parent or child (parent = 1, child = 2)
- CMP:PIN1
- Combined tag and terminal number of the wire connection attribute on the From component
- CMP:PIN2
- Combined tag and terminal number of the wire connection attribute on the To component
- SEC1
- Section value for the drawing where the From component is located
- SUB1
- Sub-section value for the drawing where the From component is located
- SEC2
- Section value for the drawing where the To component is located
- SUB2
- Sub-section value for the drawing where the To component is located
- INST1
- Installation value on the From component
- INST2
- Installation value on the To component
- IECCMP1
- IEC tag value on the From component
- IECCMP2
- IEC tag value on the To component
- PD1
- TERMDESC value on the wire connection of the From component
- PD2
- TERMDESC value on the wire connection of the To component
- SEQ1
- Wire connection sequence value of the From component
- SEQ2
- Wire connection sequence value of the To component
- PNLWDLEV1
- Panel equivalent level (WDLEV) value of the From component
- PNLWDLEV2
- Panel equivalent level (WDLEV) value of the To component
- CMPHDL1
- Entity handle value of the From component block
- CMPHDL2
- Entity handle value of the To component block
- DWGIX1
- DWGIX value, as listed in FILETIME table of project database, for the drawing where the From component is located
- DWGIX2
- DWGIX value, as listed in FILETIME table of project database, for the drawing where the To component is located
- DWGNAM1
- Drawing value (%D) for the drawing where the From component is located
- DWGNAM2
- Drawing value (%D) for the drawing where the To component is located
- CBLHDL
- Handle value for the cable marker block
- CBLINST
- Cable installation value
- CBLDWGIX
- DWGIX value, as listed in FILETIME table of project database, for the drawing where the cable marker is located
- WIREHDL1
- Entity handle for the wire connected to the From component
- WIREHDL2
- Entity handle for the wire connected to the To component
- XDIR1
- Wire connection direction code and suffix for the From component
- XDIR2
- Wire connection direction code and suffix for the To component
- PNLX1
- Wire connection's physical X-coordinate value for the From component
- PNLY1
- Wire connection's physical Y-coordinate value for the From component
- PNLZ1
- Wire connection's physical Z-coordinate value for the From component
- PNLXDIR1
- Panel wire connection direction for the From component
- PNLX2
- Wire connection's physical X-coordinate value for the To component
- PNLY2
- Wire connection's physical Y-coordinate value for the To component
- PNLZ2
- Wire connection's physical Z-coordinate value for the To component
- PNLXDIR2
- Panel wire connection direction for the To component
- CLEN
- Panel layout calculated wire length to run between the From and To components
- WIRECOLOR1
- Color value for the wire type definition for the wire connected to the From component
- WIRESIZE1
- Size value for the wire type definition for the wire connected to the From component
- USER1_1 to USER20_1
- User1-User20 values defined for the layer of the wire connected to the From component
- WIRENUM1
- Wire numbering value for the wire type definition for the wire connected to the From component; 0=no wire numbering, 1=wire numbering
- WIRECOLOR2
- Color value for the wire type definition for the wire connected to the To component
- WIRESIZE2
- Size value for the wire type definition for the wire connected to the To component
- USER1_2 to USER20_2
- User1-User20 values defined for the layer of the wire connected to the To component
- WIRENUM2
- Wire numbering value for the wire type definition for the wire connected to the To component; 0=no wire numbering, 1=wire numbering
- W01USER-W10USER
- Attribute values from the wire number block