Known Issues in Autodesk Civil 3D 2024
This document lists known issues in Autodesk Civil 3D 2024.
Autodesk Collaboration for Civil 3D |
When using Save As to save a drawing to Autodesk Docs that has references (for example, data shortcuts, surface source files, or reference templates) to a new location, the relative paths cannot be updated if the ISAVEPERCENT value is greater than 0 (0 is the default setting). This issue occurs when using Autodesk Desktop Connector 16.x. |
Autodesk Connector for ArcGIS |
In the Settings Editor dialog box, the properties of a gravity pipe cannot be changed after changing the properties of a structure, or the other way around. As a workaround, after changing the properties of a gravity pipe (or structure), click OK and then select Edit in the Import Layer dialog box to open the Settings Editor dialog box again. Then the properties of the structure (or gravity pipe) can be changed. |
When importing object types that are comprised of multiple objects (such as a multipoint object type), import settings may not be applied to all objects that are imported, which results in some objects to be imported with the default settings. |
Corridors |
When exporting a corridor transition set on a non-English version of Civil 3D, all the column headers and the Transition Type and Side values will be exported in English. |
An invalid corridor transition value may be entered into the Corridor Transition Panorama vista but no indication that the value is invalid will be displayed in the vista. When the transition is applied to the corridor, a warning will be displayed in the Event Viewer and the invalid value will not be applied to the corridor, but the invalid value will still be displayed in the Corridor Transition Panorama vista. |
Creating corridor transitions for offset assemblies is not supported. |
Data Shortcuts |
After setting the data shortcuts working folder to a new location, the project folders which have no access permission will still be displayed in the list of folders in the Prospector tree. As a workaround, you can delete the C:\Users\username\AppData\Roaming\Autodesk\C3D 2024\enu\Project Management\ShortcutFolders.xml file to reset the settings and to refresh the project folders list. |
Project Explorer |
After moving a feature line, parcel, or alignment to a different site in Civil 3D, Project Explorer is unable to display values for some properties in associated property sets. |
The Extended Data tab in the AutoCAD Properties Palette is not updated when a property set is added or removed from an object in Project Explorer when the object is currently selected in Civil 3D. The object needs to be reselected in Civil 3D in order to update the Properties Palette. |
Subassemblies |
Using subassembly PKT files that are located on a network may impact the performance of some operations. |
If subassembly PKT files used in a Civil 3D session are deleted from their folder, the subassembly node in Prospector tree must be refreshed in order to show the status of File Not Found. |