When multiple pipes enter and exit a structure, you may need to set pipe in and pipe out elevations to consistent, matching values.
This feature lets you quickly set pipe elevations in cases where multiple pipes connect to a single structure. This provides a method for quickly and accurately matching multiple pipe elevations to the invert, crown, or centerline elevation of a selected pipe.
You can also add a drop value that lets you adjust that elevation value between incoming and outgoing pipes.
Tutorial Exercise: Editing Pipe Network Parts in a Profile View
To match elevations on pipes connected to a structure
- In the drawing, right-click the structure, select Structure Properties, and then click the Connected Pipes tab.
- Press and hold the CTRL key on your keyboard and select more than one of the pipes displaying on the Connected Pipes tab.
- While still holding down the CTRL key, right-click and select one of the following options from the context menu.
- Match crowns
- Match centerlines
- Match inverts
- On the Match Elevation dialog box, click the pipe you want to match crown, centerline, or invert elevations to.
- Optionally, enter a Drop Amount to adjust the elevation by the specified value.
- Click OK to make the changes and close the Match Elevation dialog box.
- On the Connected Pipes tab, verify that the selected elevation value has been edited.
- Click Apply to make the changes, or click OK to make the changes and close the Structure Properties dialog box.