Use this dialog box to view and change pipe network-related settings.
This topic documents settings in all pipe network-related Edit Settings dialog boxes (drawing-level, feature-level, and command-level).
- Drawing-level ambient settings are identified by the
drawing icon. - Pipe network feature settings are listed near the top of this dialog box, after the General property group, and are identified by the
pipe network icon. - Pipe network command settings are identified by the
command icon.
For general information about drawing, feature, and command settings and their interaction, see Working with the Standard Settings Dialog Box Controls.
For information about drawing-level ambient settings, see Ambient Settings Tab (Drawing Settings Dialog Box)
Use these settings to establish the default styles assigned to pipe network components.
- Interference Default Style
- Structure Default Style
- Pipe Default Style
- Interference Render Material
- Structure Plan Label Style
- Pipe Plan Label Style
- Structure Profile Label Style
- Pipe Profile Label Style
- Structure Section Label Style
- Pipe Section Label Style
- Render Material
- Default Parts List
For information about style selection, see Select Style Dialog Box.
Use these settings to specify the default name formats for pipe network components (pipe network, pipes, structures). Click in the Value column, and click
to make changes in the Name Template dialog box.
Use these settings to establish the default rule set assigned to pipes and structures that are added to the pipe network.
Use these settings to establish the default settings assigned to pipe networks when they are created.
- Use Size Name From Part List as Description
-
Specifies the default method used to populate the Description field for newly created parts. When set to No, the part family name, as it is specified in the part catalog, is used to populate the part Description field. When set to Yes, the part size name, as it is specified in the parts list, is used to populate the part Description field.
Storm Sewers Migration Defaults
Use these settings to establish the defaults for part matching, and the default parts list, used when migrating pipe network data between the Storm Sewers Extension or Storm and Sanitary Analysis and AutoCAD Civil 3D.
- Part Matching Defaults
-
Specifies the defaults used for part matching when migrating pipe network data between the Storm Sewers Extension or Storm and Sanitary Analysis and AutoCAD Civil 3D. Click in the Value column, and click
to display the Part Matchup Settings dialog box for importing and exporting. For more information, see Setting Part Matching Defaults for Migration. - Parts List Used For Migration
-
Specifies the default parts list used when migrating pipe network data between the Storm Sewers Extension or Storm and Sanitary Analysis and AutoCAD Civil 3D. Click in the Value column, and click
to select a parts list. For more information, see Matching Parts Lists For Migrating Storm Sewer Data. - Allow Part Family Swapping
-
- Set to Yes if you want to allow the STM file import to overwrite the Part Family. This setting swaps parts upon import if the "expected" Part Family (from the Storm Sewers Migration Defaults or from the Part ID found in the STM file, depending on the Use Imported Part ID For Part Family setting below) is different than the current AutoCAD Civil 3D Part Family, for each part being updated.
- Set to No if you want the STM file to preserve the original part family associations. AutoCAD Civil 3D will maintain the current AutoCAD Civil 3D Part Family, regardless of the Storm Sewers Migration Defaults settings.
Setting this to No allows only dimensional values to change within the part's current Part Family, as follows:
- Diameter, or Height and Width
- Manning's n value
- Slope
- Length
- Location data (coordinates and elevations)
- Length and Width
- Location data (coordinates and elevations)
- Use Imported Part ID For Part Family
-
- For Use Imported Part ID For Part Family, do one of the following:
NoteIf Allow Part Family Swapping is set to No, then the Use Imported Part ID For Part Family setting has no effect.
- Set to Yes to allow parts to be changed to the Part Family indicated in the Part ID of the STM file. If Allow Part Family Swapping is set to Yes, and Use Imported Part ID For Part Family is set to Yes, the part's Part Family will be changed to the Part Family indicated in the Part ID of the STM file.
- Set to No to use the Import settings in the Part Matching Defaults. If Allow Part Family Swapping is set to Yes, and Use Imported Part ID For Part Family is set to No, the part's Part Family will be changed to the Part Family indicated by the Storm Sewers Migration Defaults Import settings.
- For Use Imported Part ID For Part Family, do one of the following:
Default Profile Label Placement
Use these settings to establish the default placement of profile view labels associated with the pipe network.
Default Section Label Placement
Use these settings to establish the default placement of section view labels associated with the pipe network.
- Dimension Anchor Option for Pipes
- Dimension Anchor Elevation Value for Pipes
- Dimension Anchor Plot Height Value for Pipes
- Dimension Anchor Option for Structures
- Dimension Anchor Elevation Value for Structures
- Dimension Anchor Plot Height Value for Structures
- Structure Label Placement
- Pipe Section Label Placement
and select an elevation in the drawing area.