Correcting Profile Design Criteria Violations

Product Documentation
Intermediate

Validate the profile geometry against the specified criteria and design checks.

When a profile uses the criteria-based design feature, the profile geometry must meet the design criteria specified in the design criteria file and design checks .

When a profile sub-entity violates the design criteria, a warning symbol is displayed in several locations. For information about where the warning symbols appear, see Viewing and Correcting Profile Design Criteria Violations.

You can use the warning symbols in the drawing window to view information about criteria and design checks that have been violated. When the cursor is hovered over a warning symbol in the drawing window, a tooltip displays information about the violation.

  • If a design criteria was violated, the tooltip displays the criteria that was violated, as well as the minimum value required to meet the criteria.
  • If a design check was violated, the tooltip displays the name and formula of the design check that was violated.
Note

If a sub-entity violates more than one criteria or design check, only one warning symbol is displayed in the drawing. To clear the warning symbol, the sub-entity must be modified to meet all the design criteria and design checks.

To correct profile design criteria violations using grips

  1. In the drawing window, hover the cursor over a warning symbol.

    A tooltip displays information about the violation.

  2. Select the profile.
  3. Use the profile grips to modify the profile geometry.

    The warning symbol disappears when the sub-entity meets the design criteria.

    Note

    If a sub-entity violates more than one criteria or design check, only one warning symbol is displayed on the sub-entity. To clear the warning symbol, the sub-entity must be modified to meet all the design criteria.

To correct profile design criteria violations by entering numeric values

  1. Click the profile. Click Profile tabModify Profile panelGeometry Editor.
  2. On the Profile Layout Tools toolbar, click Profile Grid View.
  3. In the Profile Entities vista, click the row that contains the warning symbol in the No. column.

    The sub-entity parameters are displayed in the Profile Layout Parameters dialog box.

  4. In the Profile Layout Parameters dialog box, locate the warning symbol in either of the following panels:
    • Layout Parameters panel — In the Value column, enter a numeric value that meets the value specified in the Constraints column.
    • Design Checks panel — Notice the design check that has been violated. Modify the profile design to meet the parameters specified in the design check.

Ribbon

Click the profile. Click Profile tabModify Profile panelGeometry Editor

Menu

Click Profiles menu Edit Profile Geometry

Command Line

EditProfileLayout

Profile Layout Tools Dialog Box Icon

Profile Layout Parameters

Profile Grid View

Dialog Boxes