Validate the profile geometry against the specified criteria and design checks.
When a profile uses the criteria-based design feature, the profile geometry must meet the design criteria specified in the design criteria file and design checks .
When a profile sub-entity violates the design criteria, a warning symbol is displayed in several locations. For information about where the warning symbols appear, see Viewing and Correcting Profile Design Criteria Violations.
You can use the
warning symbols in the drawing window to view information about criteria and design checks that have been violated. When the cursor is hovered over a warning symbol in the drawing window, a tooltip displays information about the violation.
- If a design criteria was violated, the tooltip displays the criteria that was violated, as well as the minimum value required to meet the criteria.
- If a design check was violated, the tooltip displays the name and formula of the design check that was violated.
To correct profile design criteria violations by entering numeric values
- Click the profile. Click Profile tab
Modify Profile panel
Geometry Editor
. - On the Profile Layout Tools toolbar, click
Profile Grid View. - In the Profile Entities vista, click the row that contains the
warning symbol in the No. column. The sub-entity parameters are displayed in the Profile Layout Parameters dialog box.
- In the Profile Layout Parameters dialog box, locate the
warning symbol in either of the following panels:
- Layout Parameters panel — In the Value column, enter a numeric value that meets the value specified in the Constraints column.
- Design Checks panel — Notice the design check that has been violated. Modify the profile design to meet the parameters specified in the design check.
warning symbol.