Use this tab to view or change the rule set or rule values associated with this structure.
For more information, see Structure Rules and Editing Part Rules.
This option lets you choose to override or accept the rule values as they are defined in the specified rule set. If you clear this check box, you can edit the rule values on this dialog box, and the structure uses the rule values as they are specified on this dialog box. If this option is selected, the structure uses the rule values as they are defined in the specified rule set, and those values display on this dialog box.
This rule compares all pipes connected to a single structure and ensures that pipes enter and exit the structure at logical locations. For more information, see Structure Drop Rule.
- Drop Reference Location
- Drop Value
- Maximum Drop Value
-
Specifies the maximum drop value between the lowest incoming pipe and any outgoing pipe connected to the structure. Note that this parameter provides validation only; it does not alter (move or resize) the part in the drawing in any way. It simply produces a rule violation on the part if the specified value is exceeded.
This rules checks to see if pipes entering a structure have a diameter or width that exceeds a specified maximum value. For more information, see Maximum Pipe Size Rule.
- Maximum Pipe Diameter or Width
-
For circular pipes, this parameter measures the pipe diameter. For rectangular pipes, it measures width. If a pipe diameter or width exceeds the maximum value, a warning is issued on the structure. Note that this parameter provides validation only; it does not alter (move or resize) the part in the drawing in any way. It simply produces a rule violation on the part if the specified value is exceeded.